220-1101 domain - 29% of the exam

Hardware and Network Troubleshooting

Hardware and Network Troubleshooting is 29% of the 220-1101 exam. These are the objectives it covers, each with practice questions, with every answer explained.

The domain in numbers

87
Practice questions
4
Objectives
22
Easy
22
Medium
43
Hard

Where people go wrong

  • Putting a troubleshooting step out of order

    The wrong answers pick a genuine step from the CompTIA troubleshooting methodology at the wrong point. Before the problem is identified, they offer a driver reinstall, a cable swap or a theory about the cause. Identifying the problem comes first: question the user and ask what changed. Then establish a theory of probable cause, test it, and plan and implement a fix. Documentation is the last step, so recording a cause before any work is done is out of order.

    See it in a sample question
  • Blaming firmware for lost CMOS settings

    The wrong answers blame firmware, the operating system, RAM or the motherboard when a PC loses its clock and boot order after being unplugged. A re-flash, an OS reinstall or a new board cannot make settings survive without power. The BIOS or UEFI image sits in non-volatile flash and needs no battery. The CR2032 coin cell powers the real-time clock and the volatile CMOS settings while the system is off, so a depleted cell causes exactly this reset.

    See it in a sample question
  • Mixing up thermal shutdown and power overload

    The wrong answers treat a heat fault as a power fault, or the reverse. Raising core voltage, replacing the supply or switching off the thermal protection are offered for shutdowns that a logged thermal event, a CPU reaching its thermal limit, or a cooler disturbed by a move already explains. A shutdown under CPU load calls for reseating the heatsink and reapplying thermal paste. A reboot only under graphics load, with temperatures in range, points to a supply that cannot meet peak demand.

    See it in a sample question
  • Repairing a failing drive instead of saving its data

    The wrong answers treat a dying drive as a fault a utility or setting can repair. For a clicking mechanical drive or a rising reallocated-sector count, they offer chkdsk, defragmenting, repeated scans or disabling the S.M.A.R.T. alert. These leave the physical degradation in place, and defragmenting adds head movement to a failing mechanism. The correct answers protect the data first: back up or clone to a healthy drive and replace it, or for irreplaceable photos on a clicking drive, power it down and use a recovery service.

    See it in a sample question
  • Giving one RAID level another's redundancy

    The wrong answers lend one RAID level the recovery method of another. After a drive fails in RAID 0, they offer a parity rebuild or a mirror resync, but RAID 0 stripes data with no parity and no mirror, so the data returns only from a backup. The level descriptions are swapped the same way. A two-drive mirror is RAID 1, while RAID 5 needs a minimum of three drives and survives one failure through distributed parity.

    See it in a sample question

Objectives in this domain

What to study

The official documents this domain's practice questions cite most.

Sample questions from this domain

Free sampleHardware and Network Troubleshootingeasy

A user reports a laptop that will not charge. Following the first CompTIA methodology step, which action best fits identifying the problem before any repair is attempted?

  • ASwap in a known-good charger to see whether charging resumes
  • BQuestion the user and check whether the charging light or any error appears Correct
  • COrder a replacement battery so the part is ready to fit
  • DRecord the completed repair and the outcome in the service log
Identifying the problem means questioning the user and gathering symptom details before forming a theory or attempting any fix. Step one focuses on collecting accurate information: user reports, observable indicators, and recent changes. This grounds every later step and prevents theories built on incomplete symptom data.

Why A is wrong: Swapping the charger tests a theory that the adapter is faulty, which is a later step and skips ahead of properly identifying the problem.

Why B is correct: Gathering symptoms and questioning the user is the core of step one, identifying the problem, before any theory or fix.

Why C is wrong: Preparing a part assumes the cause, but no cause has been established yet, so this jumps past both identification and theory.

Why D is wrong: Logging the outcome is the final step and cannot occur when the problem has not even been identified yet.

Free sampleHardware and Network Troubleshootinghard

Each cold boot, a user's PC shows a CMOS checksum error, the clock has reset to a date years in the past, and firmware settings revert to defaults. Once booted, the machine runs normally all day. Which action is the BEST fix?

  • AFlash the latest BIOS firmware to correct the corrupted checksum on each boot.
  • BReplace the CR2032 CMOS coin-cell battery so saved settings and the clock are retained. Correct
  • CEnter firmware setup and disable the real-time clock to stop the date resetting.
  • DReplace the motherboard, since repeatedly losing settings points to NVRAM failure.
A resetting clock plus a CMOS checksum error and lost defaults on every cold boot is the signature of a dead CR2032 coin-cell battery. The CMOS coin cell keeps the real-time clock running and preserves firmware settings while mains power is off; when it drains, the CMOS loses its stored values and the checksum fails on the next cold boot, so a fresh battery is the fix.

Why A is wrong: A checksum error hints at firmware, which is tempting, but a re-flash cannot hold settings or keep time if the coin cell can no longer power the CMOS during power-off.

Why B is correct: A depleted 3 V coin cell cannot power the CMOS and RTC while the PSU is off, which produces exactly this reset-and-checksum pattern, so replacing it restores retention.

Why C is wrong: Turning off a resetting clock sounds direct, but the RTC cannot be disabled and doing so would not restore the lost settings, so it addresses neither symptom.

Why D is wrong: A board fault can lose settings, which is tempting, but the classic pairing of a dead clock and reset defaults points to the coin cell first, so replacing the board is premature.

Free sampleHardware and Network Troubleshootinghard

A gaming PC runs fine at idle but abruptly powers off a few minutes into any CPU-intensive task. After each shutdown the BIOS health screen reports that the previous power-off was triggered by a thermal event. What is the best corrective action?

  • AReseat the CPU cooler and reapply fresh thermal paste to restore heat transfer to the heatsink. Correct
  • BRaise the CPU core voltage in the BIOS so the processor stays stable during heavy load.
  • CReplace the power supply with a higher-wattage unit to meet the load demand under stress.
  • DDisable the thermal-shutdown protection in the BIOS so the machine no longer switches off.
A load-triggered shutdown logged as a thermal event calls for restoring cooling, by reseating the cooler and reapplying thermal paste. When the CPU only overheats under load, the die is generating more heat than the heatsink can carry away; a poorly seated cooler or degraded thermal paste breaks the transfer path, so restoring proper contact is the fix rather than adding voltage, changing the PSU, or defeating the protection.

Why A is correct: Correct. A load-only shutdown logged as thermal points to poor heat transfer from a loose cooler or dried-out paste; reseating the heatsink and reapplying paste directly restores the cooling path and addresses the root cause.

Why B is wrong: Instability under load can tempt a technician toward more voltage, but higher core voltage produces more heat, which would worsen a thermal shutdown rather than resolve it.

Why C is wrong: A power-off under load looks like a PSU capacity problem, but the BIOS explicitly logs a thermal event, so wattage is not the fault and a new PSU would not stop the overheating.

Why D is wrong: Turning off the protection stops the symptom, which is why it tempts, but it removes the safeguard while the real overheating continues and risks permanent damage to the CPU.

Free sampleHardware and Network Troubleshootinghard

During POST, a workstation displays the message that a S.M.A.R.T. failure is predicted on the primary hard drive. The machine still boots to Windows and the user reports no obvious problems yet. Which action best protects the user's work?

  • ADisable S.M.A.R.T. in UEFI to clear the alert, since it is only predictive and not an actual current fault on the drive.
  • BBack up the data immediately and schedule the drive for replacement, because S.M.A.R.T. is predicting imminent failure. Correct
  • CReseat the SATA data and power cables, as a predicted S.M.A.R.T. warning is normally caused by a loose or intermittent connection.
  • DRun a full format to remap the reallocated sectors and reset the drive's internal S.M.A.R.T. counters back to a zero baseline.
Treat a S.M.A.R.T. predicted-failure alert as an early warning to back up data and replace the drive before it fails. S.M.A.R.T. tracks internal attributes such as reallocated sector counts and spin-up time; a predicted-failure state means those metrics have crossed the manufacturer's thresholds, so failure is likely soon even while the drive still operates.

Why A is wrong: Disabling S.M.A.R.T. does remove the message and the drive still boots, but it silences an early warning of failure rather than addressing it, leaving the data unprotected.

Why B is correct: A S.M.A.R.T. predicted-failure alert means monitored attributes have crossed failure thresholds; the drive works now but is degrading, so securing the data and replacing the drive is the safe response.

Why C is wrong: Cabling can cause errors, but S.M.A.R.T. predictions are based on the drive's own internal attribute thresholds, not the host cable, so reseating rarely clears a genuine prediction.

Why D is wrong: A full format does check the surface, but it cannot reset the drive's cumulative S.M.A.R.T. attributes, and reallocated sectors already indicate wear that formatting does not reverse.

Free sampleHardware and Network Troubleshootinghard

A video editor runs two SSDs in a RAID 0 array as a fast scratch volume, with no separate backup of that volume. One of the two drives fails and the array drops offline. What is the correct assessment and next step for the data on that array?

  • AAll data on the array is lost because RAID 0 stripes with no redundancy; replace the failed drive and restore from a backup. Correct
  • BRoughly half the files survive intact, because striping stores whole files on alternating drives across the array set.
  • CReplace the failed drive and rebuild from parity, since RAID 0 keeps one parity block within each stripe for recovery.
  • DThe surviving drive holds a full mirror, so removing the failed member restores immediate access to the data.
Understand that RAID 0 has no redundancy, so a single drive failure destroys the entire array and recovery depends on a backup. RAID 0 stripes data blocks across all members purely for speed and capacity, storing no parity or mirror; when any drive fails the striped data is incomplete and unrecoverable from the array itself, making an external backup the only route to recovery.

Why A is correct: RAID 0 splits data across both drives with no parity or mirror, so losing one member destroys the whole set; the only recovery is to rebuild the array and restore from an external backup.

Why B is wrong: It seems logical that half the files sit on the good drive, but RAID 0 stripes at the block level, so nearly every file spans both drives and is incomplete without the failed one.

Why C is wrong: This borrows RAID 5 behaviour; RAID 0 stores no parity at all, so there is nothing for a controller to rebuild from after a member fails.

Why D is wrong: This confuses RAID 0 with RAID 1; striping is not mirroring, so the surviving drive holds only fragments and cannot serve the data on its own.

Other domains in this exam

See also the 220-1101 cert hub, the study guide, and the cheat sheet.

Examworthy is not affiliated with or endorsed by CompTIA. Original, blueprint-aligned practice material only.